Mitsubishi Electric MELSEC Q Series Reference Manual page 217

Cc-link ie controller network
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

(c) Refresh parameters
Specify B as a target CPU-side device of transfer from LB.
Specify W as a target CPU-side device of transfer from LW.
(d) Program example
In this program example, the following processing is performed when the send request turns ON.
1.
Stores D0 data in the extended link register, and transfers them to LW0 of the CC-Link IE Controller
Network module through link refresh.
2.
Transfers data in LWD100 and LW19230 of the CC-Link IE Controller Network module to the
extended link register through link refresh, and stores them in D1 and D2 of the CPU module.
Refresh parameters are set as in Page 215, Section 6.5.2 (1) (c).
Send
request
MOV
D0
MOV
W0D100
MOV
W19230
W0
D1
D2
W1FFFF
CHAPTER 6 PARAMETER SETTING
CC-Link IE Controller
CPU module
Network module
W0
WD100
W19230
6
LW0
LWD100
LW19230
LW1FFFF
215