(c) READ instruction settings
Control data settings for the READ instruction are shown below.
Device
(S1)+0
D200
(S1)+1
D201
(S1)+2
D202
(S1)+3
D203
(S1)+4
D204
(S1)+5
D205
(S1)+6
D206
(S1)+7
D207
(S1)+8
D208
(S1)+9
D209
(S1)+10
D210
(S1)+11
D211
(S1)+12
D212 to
to
D215
(S1)+15
(S1)+16
D216
(S1)+17
D217
342
Item
Error completion type
Completion status
Channel used by own station
Target station's CPU type
Target station network No.
Target station No.
(Unused)
Number of resends
Arrival monitoring time
Read data length
(Unused)
Clock set flag
Clock data on error completion
Error-detected network No.
Error-detected station No.
Set value
0081
(Clock data at the time of error completion is set.)
H
—
(Set by the system, no setting required)
1
0000
(Control CPU)
H
1
4
0
5 times
0 (10 seconds)
5 words
0
—
(Set by the system, no setting required)