Advertisement

No.
Name
RECV execution
SB0033
request flag (4)
RECV execution
SB0034
request flag (5)
RECV execution
SB0035
request flag (6)
RECV execution
SB0036
request flag (7)
RECV execution
SB0037
request flag (8)
Network type (own
SB0040
station)
Host station's
SB0041
redundant function
support information
Power supply status of
SB0042
host
Description
Stores the data reception status of channel 4 of the own station.
OFF: No data reception
ON: Data received
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error are held.
Stores the data reception status of channel 5 of the own station.
OFF: No data reception
ON: Data received
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error are held.
Stores the data reception status of channel 6 of the own station.
OFF: No data reception
ON: Data received
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error are held.
Stores the data reception status of channel 7 of the own station.
OFF: No data reception
ON: Data received
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error are held.
Stores the data reception status of channel 8 of the own station.
OFF: No data reception
ON: Data received
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error are held.
Stores the network type of own station.
OFF: Controller network
Stores the redundant system information of the CC-Link IE Controller
Network module on the own station.
OFF: Redundant function not supported
ON: Redundant function supported
Stores the external power supply status of the CC-Link IE Controller Network
module of the own station.
OFF: External power not supplied (EXT.PW LED is OFF.)
ON: External power supplied (EXT.PW LED is ON.)
This relay is always OFF when the CC-Link IE Controller Network module
does not have the external power supply function.
APPENDICES
Availability
Control
Normal
station
station
A
571