Mitsubishi Electric MELSEC Q Series Reference Manual page 606

Cc-link ie controller network
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

No.
Name
SW01D0
Redundant system
to
status (1)
SW01D7
SW01E0
Redundant system
to
status (2)
SW01E7
604
Stores the CPU operation mode of each station (including the own station).
0: Backup mode (including single systems)
1: Separate mode
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW01D0 16 15 14 13 12 11 10
SW01D1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW01D2
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW01D3
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW01D4
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW01D5
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW01D6
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
-
-
-
-
-
SW01D7
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error are held.
• Valid only for the normally operating station at Baton pass status of each
station (SW00A0 to SW00A7).
• The reserved station and the station No. later than the largest one are
excepted.
Stores the pairing setting status of each station (including the own station).
0: No pairing setting (including single systems)
1: Pairing setting
If pairing is set, the bit corresponding to the system B station is ON.
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW01E0 16 15 14 13 12 11 10
SW01E1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW01E2
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW01E3
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW01E4
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW01E5
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW01E6
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
-
-
-
-
-
SW01E7
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error are held.
• Valid only for the normally operating station at Baton pass status of each
station (SW00A0 to SW00A7).
• The station No. later than the largest one are excepted.
Description
9
8
7
6
5
4
-
-
-
120 119 118 117 116 115 114 113
Each number in the table represents station No.
9
8
7
6
5
4
-
-
-
120 119 118 117 116 115 114 113
Each number in the table represents station No.
Availability
Control
Normal
station
station
3
2
1
3
2
1