Mitsubishi Electric MELSEC Q Series Reference Manual page 633

Cc-link ie controller network
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

MELSECNET/H
No.
Name
SW0070 to
Baton pass status of each
SW0073
station
SW0074 to
Cyclic transmission status of
SW0077
each station
SW0078 to
Parameter communication
SW007B
status of each station
SW007C to
Parameter error status of
SW007F
each station
SW0080 to
CPU operation status of each
SW0083
station (1)
SW0084 to
CPU RUN status of each
SW0087
station
SW0088 to
CPU operation status of each
SW008B
station (2)
SW008C to
Power supply status of each
SW008F
station
SW0090
Loopback information
SW0091 to
Forward loop status of each
SW0094
station
SW0095 to
Reverse loop status of each
SW0098
station
Loopback station (forward
SW0099
loop side)
Loopback station (reverse
SW009A
loop side)
SW009C to
Loop usage status of each
SW009F
station
CC-Link IE Controller Network
No.
Name
SW00A0
Baton pass status of each
to
station
SW00A7
SW00B0
Cyclic transmission status
to
of each station
SW00B7
SW00D0
Parameter communication
to
status of each station
SW00D7
SW00E0
Parameter error status of
to
each station
SW00E7
SW0100 to
CPU operation status of
SW0107
each station (1)
SW00F0
CPU RUN status of each
to
station
SW00F7
SW0110 to
CPU operation status of
SW0117
each station (2)
SW0180 to
Power supply status of each
SW0187
station
SW0065
Loopback information
SW0070
IN-side loopback station No.
OUT-side loopback station
SW0080
No.
SW0070
IN-side loopback station No.
OUT-side loopback station
SW0080
No.
SW0070
IN-side loopback station No.
SW0071
IN-side loopback factor
OUT-side loopback station
SW0080
No.
SW0081
OUT-side loopback factor
Precautions for
Compatibility
replacement
Since the line control is
executed in all stations
when stations are
disconnected or
reconnected in the CC-Link
IE Controller Network
(No. changed)
module, the baton pass
status and the cyclic
transmission status are
turned ON for up to 100ms.
(Normally for up to 50ms.)
None
(No. changed)
None
(No. changed)
• The CC-Link IE Controller
Network module does not
store the forward or
reverse loop error.
• Although the CC-Link IE
Controller Network uses
(Content
two-core cables,
changed)
loopback is performed
even if a disconnection or
error is detected on one
side.
Although the CC-Link IE
Controller Network uses
two-core cables, loopback
(Content
is performed even if a
changed)
disconnection or error is
detected on one side.
Although the CC-Link IE
Controller Network uses
two-core cables, loopback
(Content
is performed even if a
changed)
disconnection or error is
detected on one side.
APPENDICES
A
631

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qj71gp21-sxMelsec qj71gp21s-sx