Mitsubishi Electric MELSEC Q Series Reference Manual page 385

Cc-link ie controller network
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

• Devices used by the user
Device
M120
Control and request data setting command
M121
Start contact
M125
Completion device
M126
Completion status indication device
(c) REQ instruction (Remote RUN/STOP) settings
• Control data
Device
(S1)+0
D240
(S1)+1
D241
(S1)+2
D242
(S1)+3
D243
(S1)+4
D244
(S1)+5
D245
(S1)+6
D246
(S1)+7
D247
(S1)+8
D248
(S1)+9
D249
(S1)+10
D250
(S1)+11
D251
(S1)+12
to
D252 to D255
(S1)+15
(S1)+16
D256
(S1)+17
D257
• Request data
Device
(S2)+0
D260
(S2)+1
D261
(S2)+2
D262
(S2)+3
D263
Description
Item
Error completion type
Completion status
Channel used by own station
Target station's CPU type
Target station network No.
Target station No.
(Unused)
Number of resends
Arrival monitoring time
Request data length
Response data length
Clock set flag
Clock data on error completion
Error-detected network No.
Error-detected station No.
Item
Request type
Sub-request type
Operation mode
Clear mode
CHAPTER 9 DEDICATED INSTRUCTIONS
Device
Description
D240 to
Control data
D257
D260 to
Request data
D263
D265 to
Response data
D266
D604
Error code storage device
0091
(Clock data at the time of error
H
completion is set.)
(Set by the system, no setting required)
3
0000
(Control CPU)
H
1
2
0
5 times
0 (10 seconds)
3 (Remote STOP)
(Set by the system, no setting required)
0010
(When station No. is specified in
H
(S1)+5)
0002
(Remote STOP)
H
0003
(Fixed)
H
(Setting is not required for remote STOP.)
Set value
Set value
383
9