Mitsubishi Electric MELSEC Q Series Reference Manual page 207

Cc-link ie controller network
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Item
Assignment Method
Link Side
Transfer SB/SW
PLC Side
Link Side
Transfer 1 to 256
PLC Side
*1
The bit device is set in 16-point units (Start: 0
*2
Default setting according to the number of modules and the mounted position is available. (
6.5.3)
*3
The LX/LY data of the same I/O numbers with the actual I/O (the range where actual modules are mounted) must be
refreshed to the area after the actual I/O area or to any other than LX/LY.
Transfer target CPU-side devices cannot overlap with the actual I/O areas.
● Avoid any duplicate settings of the programmable-controller-side device that is used for the following.
• Refresh parameters of network modules
• Auto refresh parameters of CC-Link modules
• I/O numbers used for I/O modules and intelligent function modules
• Auto refresh parameters of intelligent function modules
• Auto refresh using the CPU shared memory of the multiple CPU system
● Set the link refresh range properly so that it does not cross over the boundary between the internal user device and the
extended data register (D) or extended link register (W).
● Set only the link devices used in the CPU module as the link refresh range.
Doing so will reduce the points of the link refresh to the CPU module, resulting in a shorter link refresh time.
● When any of the station send ranges of the link device has been changed in the control station's "Assignment the CC IE
Control Network Range", check the link refresh range of each station. (
Select a link device assignment method.
• Points/Start: Enter link device points and start I/O numbers.
• Start/End: Enter the start and end numbers of the link devices.
Dev. Name
Fixed to SB/SW
Set the SB/SW transfer range.
Points, Start, End
(Setting range: 0000
Dev. Name
Fixed to SB/SW
Set the start number of each SB/SW transfer range.
Points, Start, End
(Setting range: 0000
Select a transfer link device from the following.
Dev. Name
• LB/LW/LX/LY
Set the link device transfer range.
• LB (Setting range: 0000
Points, Start, End
• LW (Setting range: 0000
• LX/LY (Setting range: 0000
Select a transfer device from the following.
Dev. Name
• X,Y,M,L,B,T,C,ST,D,W,R,ZR (When LX is set on the Link side, C,T, and ST are
not selectable.)
Set the start number of each device transfer range.
Points, Start, End
(Setting range: Device range of CPU module)
CHAPTER 6 PARAMETER SETTING
Description
*1
to 01FF
, Default: Available
H
H
to 07FF
, Default: Available
H
H
*1
to 7FFF
, Default: Available
H
H
to 1FFFF
, Default: Available
H
H
to 1FFF
, Default: None)
H
H
to End: F
), and the word device is set in 1-point units.
H
H
Page 183, Section 6.3)
*2
)
*1
*2
)
*2
)
*2
)
*1
*1
Page 221, Section
205
6