Function
Online
Stop/restart of cyclic
operation
transmission
*1
Data of station No.65 and higher in other stations cannot be received.
*2
Cyclic data are sent to or received from the stations whose own send ranges are assigned to LB/LW 0 to 3FFF in "LB/LW
Setting(1)".
*3
Direct access to LB/LW4000 and higher is not allowed.
*4
The function is not available in the Q00UJCPU, Q00UCPU, or Q01UCPU.
(2) List of transient transmission functions
Function
Read from/write to
other station devices
(for Q/QnA series)
Transient request to
another station (for
Q/QnA series)
Link
Data send/receive (for
dedicated
Q/QnA series)
instruction
Read from/write to
other station devices
(For A series)
Remote RUN/STOP
(For Q series)
Read/write of another
station's clock data
(For Q series)
CC-Link
Read/write of another
dedicated
station's data
instruction
Access to other stations with a
programming tool
Group
Routing
Description
Disables receiving data from other stations and
sending data of its own station in a case such as
debugging. (Transient transmission is not
stopped.)
1) Safety CPU
2) Basic model QCPU
3) High Performance model QCPU
Description
Reads or writes data from or to devices of a
programmable controller on another station.
(READ/SREAD/WRITE/SWRITE instruction)
Remotely runs or stops a programmable controller
on another station. (REQ instruction)
Reads or writes clock data from or to a
programmable controller on another station. (REQ
instruction)
Sends data to a programmable controller on
another station. (SEND instruction)
Reads data received from a programmable
controller on another station. (RECV/RECVS
instruction)
Reads or writes data from or to devices of a
programmable controller on another station.
(ZNRD/ZNWR instruction)
Remotely run or stop a programmable controller
on another station. (RRUN/RSTOP instruction)
Reads or writes clock data from or to a
programmable controller on another station.
(RTMRD/RTMWR instruction)
Reads or writes the specified points of data from
the target station's device. (RIRD/RIWT
instruction)
With a programming tool allows seamless access
to the Ethernet, CC-Link IE Controller Network,
MELSECNET/H, MELSECNET/10, CC-Link IE
Field Network, and CC-Link systems.
By specifying transient transmission target stations
as a group, data can be sent to all stations of the
same group No.
Allows transient transmissions to stations located
on other networks in a multi-network system.
CHAPTER 3 SPECIFICATIONS
CPU module
Reference
1) 2) 3) 4) 5) 6)
Section 4.1.12
: Available,
: Partially available, ×: N/A
4) Process CPU
5) Redundant CPU
6) Universal model QCPU
CPU module
Reference
1) 2) 3) 4) 5) 6)
*1
*2
*1
*1
*1
*1
*3
*1
*1
*1
*1
×
*1
*1
*1
*1
*1
*2
*1
*1
*1
*1
×
Section 4.2.1
Page 324,
CHAPTER 9
*7
*7
*7
*7
*7
×
*1
*1
*1
*1
×
*1
*1
*1
*1
*1
*2
*5
×
*1
*1
*1
*1
*1
*4
Section 4.2
Page 102,
Section 4.2.2
*6
*6
*6
*6
*6
Page 103,
Section 4.2.3
section
Page 91,
3
section
Page 97,
Page 97,