8.1.4

Program example of transient transmission

The following shows a program example of transient transmission.
(1) Overview of the program example
In the program example in this section, the following transient transmission is performed using the READ and
WRITE instructions.
CPU module
D800
D849
D900
D949
CPU module
(a) Processing at control station (No. 1)-side
1.
D300 to D349 of the normal station (No. 2) is read to D800 to D849 of the control station (No. 1) with
the READ instruction.
2.
D900 to D949 of the control station (No. 1) is written to D400 to D449 of the normal station (No. 2)
with the WRITE instruction.
(b) Processing at normal station (No. 2)-side
A sequence program of the normal station (No. 2)-side is not required.
Remark
For the program example of each dedicated instruction, refer to the description of dedicated instructions. (
CHAPTER 9)
278
Control station
No.1
CC-Link IE
Controller
Network module
CC-Link IE
Controller
Network module
Normal station
No.4
CPU module
D300
D349
D400
D449
Network No.1
READ instruction
READ instruction
WRITE instruction
CPU module
Normal station
No.2
CC-Link IE
Controller
Network module
CC-Link IE
Controller
Network module
Normal station
No.3