Mitsubishi Electric MELSEC Q Series Reference Manual page 600

Cc-link ie controller network
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

No.
Name
SW0110
CPU operation status
to
of each station (2)
SW0117
SW0120
Current IN-side error
to
frame reception status
SW0127
598
Stores the continuation error status of the CPU module of each station.
(Including own station)
0: Normal
1: Continuation error
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0110 16 15 14 13 12 11 10
SW0111
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW0112
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW0113
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW0114
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW0115
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW0116
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW0117
-
-
-
-
-
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error is held.
• Valid only for the normally operating station at Baton pass status of each
station (SW00A0 to SW00A7)
• The reserved station and the station No. later than the largest one are
excepted.
Stores whether the error frame is received or not in the IN-side transmission
path of each station.
0: A line error is not occurring on the transmission path of each station's IN.
1: A line error is occurring on the transmission path of each station's IN.
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0120 16 15 14 13 12 11 10
SW0121
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW0122
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW0123
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW0124
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW0125
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW0126
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW0127
-
-
-
-
-
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error is held.
• Valid only for the normally operating station at Baton pass status of each
station (SW00A0 to SW00A7)
Description
9
8
7
6
5
4
-
-
- 120 119 118 117 116 115 114 113
Each number in the table represents station No.
9
8
7
6
5
4
-
-
- 120 119 118 117 116 115 114 113
Each number in the table represents station No.
Availability
Control
Normal
station
station
3
2
1
3
2
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qj71gp21-sxMelsec qj71gp21s-sx

Table of Contents