M800/M80/E80/C80 Series Alarm/Parameter Manual
9 Computer Link Errors (L)
9Computer Link Errors (L)
L01
Timeout error
Details
Communication ended with timeout.
(CNC has a 248-byte receive buffer. The time during which CNC receives 248 bytes exceeds the 'TIME-OUT'
value set in the I/O device parameter.
Remedy
Set a greater timeout value in the input/output device parameter.
Check the software in HOST and make sure that the HOST transmits data in response to DC1(data re-
quest) from CNC.
Set '#9614 START CODE' to '0'.
L01
Host ER signal OFF
Details
ER signal in HOST (or DR signal in CNC) is not turned ON.
Remedy
Check for any disconnected cable.
Check for any broke wire.
Make sure that the HOST power is turned ON.
L01
Parity H error
Details
Communication ended with parity H.
Remedy
Check the software in HOST and make sure that the data to be transmitted to CNC is ISO code.
L01
Parity V error
Details
Communication ended with parity V.
Remedy
Correct the data to transmit to CNC.
L01
Overrun error
Details
CNC received 10 bytes or more data from HOST in spite of DC3 (request to stop data transfer) transmission
from CNC to the HOST, which terminated the communication.
CNC received 10 bytes or more data from HOST during the data transmission from CNC to the HOST.
Remedy
Check the software in HOST and make sure that the HOST stops transmitting data within 10 bytes after
receiving DC3.
Correct the software in HOST not to transmit data such as a command or header to CNC during receiving
a machining program.