M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#9735
Host2 host type
[M8]
Select the type of the host computer.
0: UNIX/PC automatic judgment
1: UNIX
2: PC (DOS)
(Note) When "0" is set, the settings for the following parameters will be invalid.
- #9736 Wrd pos: name
- #9737 Wrd pos: size
- #9738 Wrd pos: Dir
- #9739 Wrd pos: cmnt
- #9740 Wrd num: cmnt
[C80]
Not used.
#9736
Host 2 Wrd pos: name
[M8]
Set the file name display position (nth word from left) of the list displayed when the ftp command "dir" is ex-
ecuted.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---
0 to 100
0: Default value
[C80]
Not used.
#9737
Host 2 Wrd pos: size
[M8]
Set the size display position (nth word from left) of the list displayed when the ftp command "dir" is executed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---
0 to 100
0: Default value
[C80]
Not used.
#9738
Host 2 Wrd pos: Dir
[M8]
Set the <DIR> display position (nth word from left) of the list displayed when the ftp command "dir" is execut-
ed.
(Note) One word designates a character string divided by one or more spaces.
---Setting range---
0 to 100
0: Default value
[C80]
Not used.
261
IB-1501279-H