M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1120
TofVal
Select whether to change the macro variable (tool offset) numbers for shape compensation and wear com-
pensation.
0: Not change (Conventional specification)
1: Change the shape and wear compensation variable numbers each for X, Z, and R
#1121
edlk_c
Select the edit lock for program Nos. 9000 to 9999 in memory.
0: Editing possible
1: Editing prohibited. The file cannot be opened.
(Note) If "#1122" is set to "1" or "2", "1" will be set in "#1121" when the power is turned ON.
(PR)
#1122
pglk_c
Select whether to prohibit the program display and search for program Nos. 9000 to 9999 in memory.
0: Program display and search is possible
1: Program display is impossible. Search is possible.
2: Program display and search is impossible
The program details will not be displayed, but the program No. and sequence No. will display in the prohibited
state.
(Note) If "#1122" is set to "1" or "2", "1" will be set in "#1121" when the power is turned ON.
#1123
origin
Select whether to use the origin set function.
0: Use
1: Not use
#1124
ofsfix
Select how to handle the compensation No. when the input key is pressed on the tool compensation screen.
0: Increment the compensation No. by 1 (Same as general parameters)
1: # compensation No. does not change
When setting in sequence, "0" is handier. When changing and setting repeatedly while adjusting one com-
pensation value, "1" is handier
#1125
real_f
Select the feedrate display on the monitor screen.
0: Command speed
1: Actual travel feedrate
#1126
PB_G90
Select the method to command the playback travel amount in the playback editing.
0: Incremental value
1: Absolute value
#1127
DPRINT
Select the alignment for printing out with the DPRINT function.
0: No alignment, output s printed with left justification
1: Align the minimum digit and output
#1128
RstVCI
Select how to handle the common variables when resetting.
0: Common variables won't change after resetting.
1: Common variables will be cleared #100 to #199 by resetting.
#1129
PwrVCl
Select how to handle the common variables when the power is turned ON.
0: The common variables are in the same state as before turning the power OFF.
1: Common variables will be cleared #100 to #199 when the power is turned ON.
Change macro variable
Edit lock C
Program display lock C
Origin set prohibit
Fix tool compensation No.
Actual feedrate display
Playback G90
DPRINT alignment
Clear variables by resetting
Clear variables by power-ON