16 Machine Parameters
#13556
sptc45
Specify the spindle speed at which a changeover to the 5th step's acceleration/deceleration time constant is
made when the 4th step gear is selected.
---Setting range---
0 to 99999(r/min)
#13557
sptc46
Specify the spindle speed at which a changeover to the 6th step's acceleration/deceleration time constant is
made when the 4th step gear is selected.
---Setting range---
0 to 99999(r/min)
#13558
sptc47
Specify the spindle speed at which a changeover to the 7th step's acceleration/deceleration time constant is
made when the 4th step gear is selected.
---Setting range---
0 to 99999(r/min)
#13559
spdiv41
Time constant magnification for changeover speed 1 (Gear: 11)
Specify the acceleration/deceleration time constant to be used in a range of the spindle-mode servo control/
spindle synchronization multi-step acceleration/deceleration changeover speed 1 (sptc41) to the spindle
sync multi-step acceleration/deceleration changeover speed 2 (sptc42) when the 4th step gear is selected.
Set this as a magnification with respect to the spindle-mode servo control/spindle synchronization accelera-
tion/deceleration time constant (spt4).
---Setting range---
0 to 127
#13560
spdiv42
Time constant magnification for changeover speed 2 (Gear: 11)
Specify the acceleration/deceleration time constant to be used in a range of the spindle-mode servo control/
spindle synchronization multi-step acceleration/deceleration changeover speed 2 (sptc42) to the spindle
sync multi-step acceleration/deceleration changeover speed 3 (sptc43) when the 4th step gear is selected.
Set this as a magnification with respect to the spindle-mode servo control/spindle synchronization accelera-
tion/deceleration time constant (spt4).
---Setting range---
0 to 127
#13561
spdiv43
Time constant magnification for changeover speed 3 (Gear: 11)
Specify the acceleration/deceleration time constant to be used in a range of the spindle-mode servo control/
spindle synchronization multi-step acceleration/deceleration changeover speed 3 (sptc43) to the spindle
sync multi-step acceleration/deceleration changeover speed 4 (sptc44) when the 4th step gear is selected.
Set this as a magnification with respect to the spindle-mode servo control/spindle synchronization accelera-
tion/deceleration time constant (spt4).
---Setting range---
0 to 127
Spindle sync multistep acceleration/deceleration
changeover speed 5 (Gear: 11)
Spindle sync multistep acceleration/deceleration
changeover speed 6 (Gear: 11)
Spindle sync multistep acceleration/deceleration
changeover speed 7 (Gear: 11)
Time constant magnification for changeover speed 1
(Gear: 11)
Time constant magnification for changeover speed 2
(Gear: 11)
Time constant magnification for changeover speed 3
(Gear: 11)
579