M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P612
Exponential function error
Details
A travel command for exponential interpolation was issued during mirror image for facing tool posts.
Remedy
Correct the program.
P650
Sub sys identification # error
Details
The identification No. specified in the address B of G122 or G144 is that of the part system where G122
is given.
The identification No. specified in the sub part system control I command (G122) is not set in the parameter
#12049 SBS_no.
Remedy
Change the address B of G122 or G144 to be any identification No. other than that of the part system
where G122 is given.
Select the identification No. for the sub part system control I command (G122) from among the available
Nos.
Specify the identification No. you wish to use for the sub part system control I command (G122) in the pa-
rameter #12049 SBS_no.
P651
Other G code in sub sys block
Details
G122 or G144 has been given together with any other G code command in a block.
Remedy
Do not command G122 or G144 together with any other G code command in a block.
P652
Illegal mode (sub part system)
Details
G122 or G144 has been commanded in any of the following modes.
User macro modal call (G66, G66.1)
High-speed mode (G5, G5.1)
Remedy
Cancel the following modes before commanding G122 or G144.
User macro modal call (G66, G66.1)
Fixed cycle mode
High-speed mode (G5, G5.1)
P653
Illegal G code (sub part sys)
Details
High-speed mode command (G5, G5.1) has been given in a sub part system.
Remedy
Do not use the high-speed mode (G5, G5.1) in a sub part system.
P656
Illegal PLC device
Details
Specified the device other than R register/D register.
Specified the odd numbered device when 4 byte is specified.
Specified the device number that is out of the command range.
Specified the data length that is out of the command range.
Specified the bit number that is out of the command range.
Omitted the device number.
Omitted the project number after ",P".
Omitted the data length after ",".
Omitted the bit number after ".".
Remedy
Check the program.