M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P612

Exponential function error

Details
A travel command for exponential interpolation was issued during mirror image for facing tool posts.
Remedy
Correct the program.
P650

Sub sys identification # error

Details
The identification No. specified in the address B of G122 or G144 is that of the part system where G122
is given.
The identification No. specified in the sub part system control I command (G122) is not set in the parameter
#12049 SBS_no.
Remedy
Change the address B of G122 or G144 to be any identification No. other than that of the part system
where G122 is given.
Select the identification No. for the sub part system control I command (G122) from among the available
Nos.
Specify the identification No. you wish to use for the sub part system control I command (G122) in the pa-
rameter #12049 SBS_no.
P651

Other G code in sub sys block

Details
G122 or G144 has been given together with any other G code command in a block.
Remedy
Do not command G122 or G144 together with any other G code command in a block.
P652

Illegal mode (sub part system)

Details
G122 or G144 has been commanded in any of the following modes.
User macro modal call (G66, G66.1)
High-speed mode (G5, G5.1)
Remedy
Cancel the following modes before commanding G122 or G144.
User macro modal call (G66, G66.1)
Fixed cycle mode
High-speed mode (G5, G5.1)
P653
Illegal G code (sub part sys)
Details
High-speed mode command (G5, G5.1) has been given in a sub part system.
Remedy
Do not use the high-speed mode (G5, G5.1) in a sub part system.
P656
Illegal PLC device
Details
Specified the device other than R register/D register.
Specified the odd numbered device when 4 byte is specified.
Specified the device number that is out of the command range.
Specified the data length that is out of the command range.
Specified the bit number that is out of the command range.
Omitted the device number.
Omitted the project number after ",P".
Omitted the data length after ",".
Omitted the bit number after ".".
Remedy
Check the program.
IB-1501279-H