M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
M01
Sp-Sp polygon cut interlock
Details
Cutting feed is in wait state until synchronization is completed.
Remedy
Wait for the synchronization to end.
M01
Mixed sync ctrl prmtr illegal
Details
There is a mistake in the settings of mixed control axis parameters (crsax [1] to [8]).
Mixed control was attempted within one and the same part system.
Any of the parameter settings is disabling mixed control.
Remedy
Check the parameter settings for mixed synchronization control.
M01
Mixed sync ctrl disable modal
Details
Mixed synchronization control was commanded for a part system in which mixed synchronization control is dis-
abled as shown below.
During nose R compensation mode
During pole coordinate interpolation mode
During cylindrical interpolation mode
During balance cut mode
During fixed cycle machining mode
During facing turret mirror image
During constant surface speed control mode
During hobbing mode
During axis name switch
During interference check III alarm (interference detection, interference alarm area intrusion or interfer-
ence warning area intrusion)
An axis was transferred to another part system, and mixed control was attempted with the part system's max-
imum number of control axes exceeded.
An axis was removed from the part system, and mixed control was attempted with the part system's number of
axes zero.
Another axis exchange was attempted to the axis which was already transferred to another part system for
mixed control.
Mixed control was attempted with an axis of a part system not in automatic operation.
Remedy
Correct the program.
M01
Synchro ctrl setting disable
Details
"Synchronous control operation method" was set (with R2589) when the mode was not the C axis mode.
"Synchronous control operation method" was set (with R2589) in the zero point not set state.
Mirror image is disabled.
External mirror image or parameter mirror image was commanded during facing turret mirror image.
You have set the "Synchronous control operation method" (R2589) of multiple axis synchronization, although
the multiple axis synchronization control cannot be used.
Remedy
Set the contents of the R2589 register to "0".
Correct the program and parameters.
M01
Synchro start/cancel disable
Details
Synchronous control start/cancel command was issued when the start/cancel is disabled.
Remedy
Correct the program and parameters.
27
1033
1034
1035
1036
1037
IB-1501279-H