M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#1569
SfiltG0
Set the filter time constant for smoothly changing the acceleration rate for the rapid traverse acceleration/
deceleration in pre-interpolation acceleration/deceleration.
---Setting range---
0 to 200 (ms)
#1570
Sfilt2
Set the filter time constant for smoothly changing the acceleration rate in pre-interpolation acceleration/de-
celeration.
This will be disabled when "0" or "1" is set.
- Notch frequency Hz
Displays the notch frequency (Hz) for the S-shape filter set in "#1570 Sfilt2" (Soft acceleration/deceleration
filter 2).
---Setting range---
0 to 200 (ms)
#1571
SSSdis
Fix the shape recognition range for SSS control.
---Setting range---
0/1
#7914
ROT_PREFILT
Set the time constant for rotary axis prefilter.
Setting this parameter can smoothen the tool angle change (rotary axis' motion) under tool center point con-
trol.
Possible to do this setting on [High-accuracy parameter] screen, which you can reach by going to [Setup]
Screen and selecting [User parameter].
When set to "0", "Rotary axis prefiltering" will be disabled.
---Setting range---
0 to 200 (ms)
G00 soft acceleration/deceleration filter
Soft acceleration/deceleration filter 2
SSS control adjustment coefficient fixed value selec-
tion
Rotary axis prefilter time constant