M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P250
No spec: Figure rotation
Details
Figure rotation (M98 I_J_P_H_L_) was commanded though it is out of specifications.
Remedy
Check the specifications.
P251
Figure rotation overlapped
Details
Figure rotation command was issued during figure rotation.
Remedy
Correct the program.
P252
Coord rotate in fig. rotation
Details
A coordinate rotation related command (G68, G69) was issued during figure rotation.
Remedy
Correct the program.
P260
No spec: Coordinates rotation
Details
A coordinate rotation command was issued though it is out of specifications.
Remedy
Check the specifications.
P261
G code illegal (Coord rot)
Details
Another G code or a T command has been issued in the block of coordinate rotation command.
Remedy
Correct the program.
P262
Illegal modal (Coord rot)
Details
A coordinate rotation command has been issued during modal in which coordinate rotation is not allowed.
Remedy
Correct the program.
P270
No spec: User macro
Details
A macro specification was commanded though it is out of specifications.
Remedy
Check the specifications.
P271
No spec: Macro interrupt
Details
A macro interruption command has been issued though it is out of specifications.
Remedy
Check the specifications.
P272
NC and macro texts in a block
Details
An executable statement and a macro statement exist together in the same block.
Remedy
Place the executable statement and macro statement in separate blocks in the program.
139
IB-1501279-H