No Spec: Herical Cutting; No Spec: Spiral Cutting; Can't Calculate 3Dim Arc; 3Dim Arc Illegal - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P72

No spec: Herical cutting

Details
A helical command has been issued though it is out of specifications.
Remedy
Check whether the specifications are provided for the helical cutting.
An Axis 3 command has been issued by the circular interpolation command. If there is no helical specifi-
cation, move the linear axis to the next block.
P73

No spec: Spiral cutting

Details
A spiral command was issued though it is out of specifications.
Remedy
Issue the G02.1 and G03.1 commands for circular interpolation.
Check whether the specifications are provided for the spiral cutting.
P74

Can't calculate 3DIM arc

Details
The 3-dimension circular cannot be obtained because the end block was not specified during 3-dimension cir-
cular interpolation supplementary modal.
The 3-dimension circular cannot be obtained due to an interruption during 3-dimension circular interpolation
supplementary modal.
Remedy
Correct the program.
P75

3DIM arc illegal

Details
An illegal G code was issued during 3-dimension circular interpolation modal.
Otherwise, 3-dimension circular interpolation command was issued during a modal for which a 3-dimension cir-
cular interpolation command cannot be issued.
Remedy
Correct the program.
P76
No spec: 3DIM arc interpolat
Details
G02.4/G03.4 was commanded though there is no 3-dimension circular interpolation specification.
Remedy
Check the specifications.
P90
No spec: Thread cutting
Details
A thread cutting command was issued though it is out of specifications.
Remedy
Check the specifications.
P93
Illegal pitch vaule
Details
An illegal thread lead (thread pitch) was specified at the thread cutting command.
Remedy
Correct the thread lead for the thread cutting command.
P100
No spec: Cylindric interpolat
Details
A cylindrical interpolation command was issued though it is out of specifications.
Remedy
Check the specifications.
IB-1501279-H
128

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents