M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
M01
R-pnt ret invld at abs pos alm
Details
A reference position return signal was enabled during an absolute position detection alarm.
Remedy
Reset the absolute position detection alarm, and then perform the reference position return.
M01
R-pnt ret invld at zero pt ini
Details
A reference position return signal was input during zero point initialization of the absolute position detection
system.
Remedy
Complete the zero point initialization, and then perform reference position return.
M01
High-accuracy skip disabled
Details
The drive unit's hardware or software does not conform to the high-accuracy skip.
Remedy
The software or hardware does not conform to the function. Contact service center.
M01
Hi-ac skip coord retrieval err
Details
Failed to retrieve the skip coordinate value from the drive unit.
Remedy
Check the wiring.
Check the parameters.
M01
Now skip on
Details
The "skip input" signal remains enabled when the operation has shifted from skip retract to measurement.
Remedy
Increase the skip retract amount.
M01
No skip
Details
Even though the 1st skip was to the correct position, the 2nd skip could not be found.
Remedy
Check whether the measurement target has moved.
M01
Rtn dir err in manual measure
Details
Return direction in manual measurement is the opposite of the parameter setting.
Remedy
Check the setting of the parameter "#2169 Rtn dir err in manual measure" (Return direction in manual
measurement).
Move the axis manually in the direction to a safe position, then reset.
M01
No specifications
Details
The specification is not supported.
Remedy
Check the specifications.