M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1478
F-bus Card 1 OFF
[M8]
Select whether to enable or disable the Fieldbus communication expansion card mounted in the slot EXT3
(or EXT1 for M80/M800S/E80).
0: Enable (default)
1: Disable
(Note) This parameter is enabled for all the communication expansion cards, except CC-Link expansion
card.
(PR)
#1479
F-bus Card 2 OFF
[M8]
Select whether to enable or disable the Fieldbus communication expansion card mounted in the slot EXT4
(or EXT2 for M80/M800S/E80).
0: Enable (default)
1: Disable
(Note) This parameter is enabled for all the communication expansion cards, except CC-Link expansion
card.
(PR)
#1480
tp_invalid
Select whether to disable input via touch panel.
0: Enable touch panel operation
1: Disable touch panel operation
(PR)
#1481
Enable S-Safety
Select whether to enable smart safety observation.
0: Disable
1: Enable
(PR)
#1483
SBS1_sys num
Specify the number of sub part systems to be used for Sub part system control I in M80/M80W.
The specified number of part systems counted from the end of the system's effective part systems are treated
as sub part systems.
(Note) For M800, this setting is ignored. (All the effective part systems can be used as main or sub part sys-
tem.)
---Setting range---
0 to 7
#1487
ITF3_Spec
bit0: Speed clamp specifications at entering the interference warning area
In interference check III, select whether to perform speed clamp and torque limit in only the part systems re-
lating to the interference warning or in all the part systems at entering the interference warning area.
0: Perform in only the part systems relating to the interference warning
1: Perform in all the part systems and axes
(PR)
#1488
ITF3 valid
Interference check III is validated.
When interference check III is invalid, interference check between part systems is valid.
0: Interference check III invalid
1: Interference check III valid
(PR)
#1489
SLMP_on
[M8]
Select whether to enable or disable the SLMP server function.
0: Disable
1: Enable
[C80]
Not used.
Fieldbus communication extension card 1 OFF
Fieldbus communication extension card 2 OFF
Disable touch panel operation
Enable smart safety observation
Number of sub systems to use in sub part system con-
trol I
Interference check III specification
Interference check III valid
SLMP_on
453
IB-1501279-H