1 Operation Errors (M)
M01
No spec: Spatial error comp
Details
The spatial error compensation option is not available.
Remedy
Check the specifications.
M01
Spatial error comp excessive
Details
The compensation amount is outside the setting range.
Due to the calculation of the excessive amount, it is clamped by +/-1mm.
Remedy
Set the compensation amount within the setting range.
M01
Auto backlash adjust illegal
Details
A measurement condition adjustment or backlash adjustment was attempted to an axis with which auto-
matic backlash adjustment is impossible.
A measurement condition adjustment or backlash adjustment was attempted even though all the axes had
not reached the 1st reference position.
The operation mode is other than memory mode.
The slave axis of synchronous control is selected as adjustment axis.
An attempt has been made to start an adjustment by cycle start.
Remedy
Check the adjustment axis.
Start the adjustment after all the axes return to the 1st reference position.
Check the operation mode.
Select the master axis of synchronous control as adjustment axis when adjusting the slave axis.
Start the adjustment by automatic backlash adjustment start signal.
M01
Operating auto backlash adjust
Details
An illegal operation was attempted during measurement condition adjustment or backlash adjustment.
Remedy
Continue the operation after canceling the measurement condition adjustment and backlash adjustment.
M01
APLC password mismatch
Details
The APLC authentication password is inconsistent.
Remedy
Contact the machine tool builder.
M01
High-cycle sampling disabled
Details
The drive unit's hardware or software does not conform to the high-cycle sampling mode.
High-cycle data are not used even when high-cycle sampling has been set.
High-cycle sampling was attempted while the axis targeted for high-cycle sampling was moving.
High-cycle sampling was attempted during speed monitor mode.
High-cycle sampling was attempted while any of the following operations is being executed: Dog-type zero
point return, absolute position setting, synchronous tapping, spindle synchronization, hobbing, tool spindle
synchronization IC.
Remedy
The software or hardware does not conform to the function. Contact service center.
Set data for high-cycle sampling.
Execute high-cycle sampling after stopping the axis targeted for high-cycle sampling.
Execute high-cycle sampling after cancelling the speed monitor mode.
Execute high-cycle sampling after stopping the currently executed functions.
IB-1501279-H
22
0260
0261
0270
0271
0280
0290