Illegal Tip Point; No Spec: 3D Tool R Comp; Disable Cmd In 3D Tool R Comp; 3D Tool R Comp Is Disabled - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
12 Program Errors (P)
P158

Illegal tip point

Details
An illegal tip point No. (other than 1 to 8) was found during G46 nose R compensation.
Remedy
Correct the tip point No.
P161

No spec: 3D tool R comp

Details
3-dimensional tool radius compensation (tool vertical direction compensation) is not included in the specifica-
tions.
Remedy
Check the specifications.
P162

Disable Cmd in 3D tool R comp

Details
A command (G or T command, etc.) was issued during 3-dimensional tool radius compensation (tool vertical
direction compensation), although it is disabled during the compensation.
Remedy
Cancel 3-dimensional tool radius compensation (tool vertical direction compensation).
P163

3D tool R comp is disabled

Details
3-dimensional tool radius compensation (tool vertical direction compensation) was commanded in a mode
where the command is disabled.
Remedy
Cancel the mode that disables the command.
P170
No offset number
Details
No compensation No. (DOO, TOO or HOO) command was given when the radius compensation (G41,
G42, G43 or G46) command was issued. Otherwise, the compensation No. is larger than the number of
sets in the specifications.
H99 or D99 is commanded with the parameter "#1227 aux11/bit1" enabled when the length compensation
method and radius compensation method are set to "1" or "2" for the M system tool life management II.
Remedy
Add the compensation No. command to the compensation command block.
Check the number of sets for the tool compensation Nos. and correct the compensation No. command to
be within the number of sets.
H99 and D99 commands cannot be used when the length compensation method and radius compensation
are set to "1" or "2". Set the length compensation method and radius compensation method to "0".
P171
No spec:Comp input by prog G10
Details
Compensation data input by program (G10) was commanded though it is out of specifications.
Remedy
Check the specifications.
P172
G10 L number error
Details
An address of G10 command is not correct.
Remedy
Correct the address L No. of the G10 command.