16 Machine Parameters
#2660

omrff_inps

Specify the in-position width at which the standard model gain is switched under OMR-FF control.
When set to "0", command deceleration check is performed.
---Setting range---
0.000 to 99.999 (mm)
#2661

ITF3_ILMT

In interference check III, select whether to limit the torque at entering the interference warning area.
0: No torque limit
(Use "#2213 SV013 (Current limit value)")
1: Limit the torque
(Use "#2214 SV014 (Current limit value in special control)")
(Note) This setting is invalid if spindle/C axis is the target axis. (Torque cannot be limited.)
#2662

ITF3_Clamp

In interference check III, if clamping the speed, the clamp speed is set at entering the interference warning
area.
(Note) When "0" is set, the speed will not be clamped.
---Setting range---
0 to 1000000 (mm/min)
#2663

IDD CauThreshold

[C80]
Set the threshold so that "Z38 Insulation deterioration wrn 0001" could occur.
When performing the insulation deterioration detection and the detected value falls below the parameter set-
ting value, "Z38 Insulation deterioration wrn 0001" occurs.
If "0" is set, the standard value (100[0.1 megohm]) will be applied.
---Setting range---
0 to 300 (0.1 megohm)
#2664
IDD ChgThreshold
[C80]
Set the threshold so that "Z38 Insulation deterioration wrn 0002" could occur.
When performing the insulation deterioration detection and the detected value falls below the parameter set-
ting value, "Z38 Insulation deterioration wrn 0002" occurs.
If "0" is set, the standard value (10[0.1 megohm]) will be applied.
---Setting range---
0 to 300 (0.1 megohm)
(PR)
#2674
primno
[M8]
The parameter setting is used for the multiple axis synchronization control.
Specify the master axis No. that corresponds to the axis.
Enter the sequential NC axis No., with the 1st axis of the 1st part system set as 1.
You cannot set the No. of the axis targeted for the multiple axis synchronization control in #1068(slavno).
You cannot set #1068(slavno) for the axis targeted for the multiple axis synchronization control.
The master axis for multiple axis synchronization control cannot be set in primno.
For a multi-part system configuration, you cannot set the axes across different part systems.
---Setting range---
0: No master axis
1 to 32: 1st to 32nd axis
IB-1501279-H
OMR-FF in-position width
Interference check III torque limit at entering interfer-
ence warning area
Interference check III clamp speed at entering interfer-
ence warning area
Motor insulation deterioration: Caution threshold
Motor insulation deterioration: Replacement threshold
Multiple axis synchronization control: Master axis No.