#2281
SV081 SPEC2
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F-A:
Not used. Set to "0".
bit 9: npg Earth fault detection
0: Disable
Set "0" and it is constantly "Enable" for MDS-EJ/EJH Series.
bit 8:
Not used. Set to "0".
bit 7: szchk Distance-coded reference scale reference mark
0: Check at 4 points (standard)
bit 6-4:
Not used. Set to "0".
bit 3: absc Distance-coded reference scale
0: Disable
bit 2-0:
Not used. Set to "0".
1: Enable (standard)
1: Check at 3 points
1: Enable
Servo specification 2
absc
szchk
npg