M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#24124+15(m-1)
[M8]
Set the station No. of the connected remote, local and intelligent stations.
Set "0" when no setting is required.
"m" means the m-th connected station in ascending order of station No. (m= 1 to 64)
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set to "0".
---Setting range---
0 to 64
#24125+15(m-1)
[M8]
Select the number of points of the connected remote station.
"m" means the m-th connected station in ascending order of station No. (m= 1 to 64)
The details of setting values differ with each protocol version and station type.
Protocol: Ver.2 (station type: Ver.1, remote I/O station)
0: 0 point (reserved station)
1: 8 points
2: 8 points + 8 points reserved
3: 16 points
4: 32 points
Setting 0 is valid only for the reserved station. When 0 is set for the other stations, the number of points
will be 32.
Set the value so that the total number of points of remote I/O stations connected in series will be multiple
of 16.
(Example 1) 2 units of 8 points I/O: Set "1" for each
(Example 2) 3 units of 8 points I/O: Set "1" for the first and the second I/O, "2" for the third.
Protocol: Ver.2 (station type: Ver.1 except remote I/O station)
0: 0 point (reserved station)
1 to 4: Automatically calculated
0 point is valid only for the reserved station. When 0 is set for the other stations, the number of points will
be automatically calculated.
Unless 0 is set, the number of points will be automatically calculated with the number of occupied stations
and the setting value of the extended cycling.
Protocol: Ver.1 (for all station types)
0 to 4: Automatically calculated
0 cannot be set even for the reserved station.
Automatically calculated with the setting value of the number of occupied stations.
---Master station---
Set a value corresponding to the protocol version and the station type.
---Local/standby master station---
Set to "0".
CNm station No.
CNm remote sta pt