16 Machine Parameters
#2283
SV083 SSF6
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F-8 :
Not used. Set to "0".
bit 7-5 : nfd5 Depth of Notch filter 5
Set the depth of Notch filter 5 (SV088).
bit7,6,5=
000: -∞
001: -18.1[dB]
010: -12.0[dB]
011: -8.5[dB]
100: -6.0[dB]
101: -4.1[dB]
110: -2.5[dB]
111: -1.2[dB]
bit 4 :
Not used. Set to "0".
bit 3-1 : nfd4 Depth of Notch filter 4
Set the depth of Notch filter 4 (SV087).
bit3,2,1=
000: -∞
001: -18.1[dB]
010: -12.0[dB]
011: -8.5[dB]
100: -6.0[dB]
101: -4.1[dB]
110: -2.5[dB]
111: -1.2[dB]
bit 0 :
Not used. Set to "0".
Servo function 6