16 Machine Parameters

16.18 Macro List

#7001
M[01] Code
Set the M code used for calling out the macro with the M command.
Select codes to be entered other than the codes basically required by the machine and M codes of M0, M1,
M2, M30, M96 through M99, and M198.
This is valid when "#1195 Mmac" is set to "1".
---Setting range---
0 to 9999
#7002
M[01] TYPE
Set the macro call out type.
0: Equivalent to M98 P****;
1: Equivalent to G65 P****;
2: Equivalent to G66 P****;
3: Equivalent to G66.1 P****;
4: Equivalent to G144 D0 A****;
(Sub part system control II complete wait method)
5: Equivalent to G144 D1 A****;
(Sub part system control II parallel process method)
#7003
M[01] Program No.
Set the No. of the program or file name to be called out. The file name can contain up to 32 characters.
---Setting range---
Program name or file name (up to 32 characters)
#7011
M[02] Code
The setting method is same as "#7001".
#7012
M[02] Type
The setting method is same as "#7002".
#7013
M[02] Program No.
The setting method is same as "#7003".
#7021
M[03] Code
The setting method is same as "#7001".
#7022
M[03] Type
The setting method is same as "#7002".
#7023
M[03] Program No.
The setting method is same as "#7003".
#7031
M[04] Code
The setting method is same as "#7001".
#7032
M[04] Type
The setting method is same as "#7002".
#7033
M[04] Program No.
The setting method is same as "#7003".
#7041
M[05] Code
The setting method is same as "#7001".
#7042
M[05] Type
The setting method is same as "#7002".
#7043
M[05] Program No.
The setting method is same as "#7003".