16 Machine Parameters
#1181
G96_ax
Select the axis to be targeted for constant surface speed control.
0: Program setting will be disabled, and the axis will always be fixed to the 1st axis
1: 1st axis
2: 2nd axis
3: 3rd axis
:
16: 16th axis
However, when set to other than "0", the priority will be on the program setting.
#1182
thr_F
Set the retract speed when not using chamfering in the thread cutting cycle.
0: Cutting feed clamp feedrate
1 to 60000 mm/min: Setting feedrate
---Setting range---
0 to 60000 (mm/min)
#1183
clmp_M
Set the M code for C axis clamp in hole drilling cycle.
---Setting range---
0 to 99999999
#1184
clmp_D
Set the dwell time after outputting the M code for C axis unclamp in hole drilling cycle.
---Setting range---
0.000 to 99999.999 (s)
#1185
spd_F1
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F1 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be increased/de-
creased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)
#1186
spd_F2
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F2 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be increased/de-
creased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)
#1187
spd_F3
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F3 is issued (mm/min)
When "#1246 set08/bit6" is set to "1" and F 1-digit feed is commanded, the feedrate can be increased/de-
creased by operating the manual handle.
---Setting range---
0 to 1000000 (mm/min)
IB-1501279-H
Constant surface speed axis
Thread cutting speed
M code for clamp
Dwelling time after outputting M code for unclamp
F1 digit feedrate F1
F1 digit feedrate F2
F1 digit feedrate F3