M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#24126+15(m-1)
[M8]
Set the reserved/error invalid station.
"m" means the m-th connected station in ascending order of station No. (m= 1 to 64)
0: No setting
1: Reserved station
2: Error invalid station
(Note) Refer to "CC-Link System Master/Local Module User's Manual (SH(NA)-080394E)" for the details of
the functions.
---Master station---
Set either of "0" to "2".
---Local/standby master station---
Set to "0".
#24131+15(m-1)
[M8]
Set the allocation of the buffer memory size to the local station, standby master station and intelligent device
station when in transient transmission.
"m" means the m-th connected station in ascending order of station No. (m= 1 to 64)
Set "0" when no setting is required.
(Note) The total size of the send/receive buffers must be 4096 (words) or less.
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set to "0".
---Setting range---
0, 64 to 4096 (words)
#24132+15(m-1)
[M8]
Set the allocation of the buffer memory size to the local station, standby master station and intelligent device
station when in transient transmission.
"m" means the m-th connected station in ascending order of station No. (m= 1 to 64)
Set "0" when no setting is required.
(Note) The total size of the send/receive buffers must be 4096 (words) or less.
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set to "0".
---Setting range---
0, 64 to 4096 (words)
IB-1501279-H
CNm set rsvd sta
CNm send size
CNm receive size
672
Reserved station
Send buffer size
Receive buffer size