M800/M80/E80/C80 Series Alarm/Parameter Manual
1 Operation Errors (M)
M01
Cross control axis exists
Details
A manual travel command has been given to the axis being exchanged when manual interruption is disabled
under cross machining control (when "#1435 crsman" = 0).
Remedy
This error can be cancelled by either one of the following operations.
1: Cancel the manual travel command
2: Reset the NC
M01
Arbitrary ax superimp. sys err
Details
Arbitrary axis superimposition command has been issued in any part system other than the one that con-
tains either the basic or superimposed axis of arbitrary axis superimposition control.
Arbitrary axis superimposition cancel command has been issued in any part system other than the one
that contains the superimposed axis of arbitrary axis superimposition control.
Remedy
Correct the program so that the arbitrary axis superimposition command is given in an appropriate part
system.
M01
Spindle speed fluctuation
Details
The actual spindle speed has fluctuated exceeding the allowable range, while spindle speed fluctuation detec-
tion (G162) is active.
The number following "S", which is output together with this alarm, indicates the spindle where speed fluctua-
tions were detected.
Remedy
Unnecessarily large load may be applied to the spindle during automatic operation.
Reduce the spindle load.
To prevent this alarm from being output during spindle speed fluctuation detection (G162), set the param-
eter #1242 set14 BIT2 to ON.
M01
Sp synchro phase calc illegal
Details
Spindle synchronization phase alignment command was issued while the "phase shift calculation request" sig-
nal was ON.
Remedy
Correct the program.
Correct the sequence program.
M01
Illegal cmd in SP oscillation
Details
A function that cannot be used with spindle oscillation was commanded during spindle oscillation.
Remedy
Command the function after finishing spindle oscillation.
M01
SP oscillation cmd illegal
Details
Spindle oscillation was commanded during executing a function that cannot be used with spindle oscillation.
Remedy
Command spindle oscillation after finishing the function that cannot used with spindle oscillation.
M01
SP oscillation set val illegal
Details
Spindle oscillation was commanded while a value out of range is set as spindle oscillation amplitude or spindle
oscillation frequency.
Remedy
Check the setting values of the amplitude and frequency.