15 User Parameters

15.15 Menu Selection Parameters

(PR)
#10501-

Monitr main menu 1 to 30

10530
Select the menu Nos. to be displayed on Monitor screen's main menus.
Set the menu No. (numbered in the initial order) which you wish to set first from the left of Monitor's main
menus in #10501, second in the next parameter and likewise afterwards.
(Ex.) When you set the parameter #10501 to 11, the menu initially displayed at the left end of Monitor main
menu's 2nd page is displayed at the left end of the 1st page.
(Note) If you set the No. of menu which is not displayed in the initial state (without setting the menu selection
parameters), the menu won't be displayed after this parameter setting.
[M8]
The menu position of each parameter and the menu when "0" is set are as follows.
#10501: First from left in the page 1 (when "0" is set: Search)
#10502: Second from left in the page 1 (when "0" is set: Reserch)
#10503: Third from left in the page 1 (when "0" is set: Edit)
#10504: Fourth from left in the page 1 (when "0" is set: Trace)
#10505: Fifth from left in the page 1 (when "0" is set: Check)
#10506: Sixth from left in the page 1 (when "0" is set: Offset)
#10507: Seventh from left in the page 1 (when "0" is set: Coord)
#10508: Eighth from left in the page 1 (when "0" is set: W-shift)
#10509: Ninth from left in the page 1 (when "0" is set: Not display)
#10510: Tenth from left in the page 1 (when "0" is set: Dsp sw.)
#10511: First from left in the page 2 (when "0" is set: Modal)
#10512: Second from left in the page 2 (when "0" is set: Tree)
#10513: Third from left in the page 2 (when "0" is set: Time)
#10514: Fourth from left in the page 2 (when "0" is set: Com var)
#10515: Fifth from left in the page 2 (when "0" is set: Loc var)
#10516: Sixth from left in the page 2 (when "0" is set: P corr)
#10517: Seventh from left in the page 2 (when "0" is set: PLC SW)
#10518: Eighth from left in the page 2 (when "0" is set: G92 set)
#10519: Ninth from left in the page 2 (when "0" is set: Col stp)
#10520: Tenth from left in the page 2 (when "0" is set: LdMeter)
#10521: First from left in the page 3 (when "0" is set: Sp-stby)
#10522: Second from left in the page 3 (when "0" is set: TipDisp)
#10523: Third from left in the page 3 (when "0" is set: All sp)
#10524: Fourth from left in the page 3 (when "0" is set: Not display)
#10525: Fifth from left in the page 3 (when "0" is set: Not display)
#10526: Sixth from left in the page 3 (when "0" is set: S-sel)
#10527: Seventh from left in the page 3 (when "0" is set: Next Ax)
#10528: Eighth from left in the page 3 (when "0" is set: Cnt exp)
#10529: Ninth from left in the page 3 (when "0" is set: Cnt set)
#10530: Tenth from left in the page 3 (when "0" is set: MST)