Sv013 Ilmt; Sv014 Ilmtsp; Sv015 Ffc; Sv016 Lmc1 - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#2213

SV013 ILMT

Set the current (torque) limit value in a normal operation.
This is a limit value in forward run and reverse run (for linear motors: forward and reverse direction).
When the standard setting value is "800", the maximum torque is determined by the specification of the mo-
tor.
Set this parameter as a proportion (%) to the stall current.
---Setting range---
0 - 999 (Stall current %)
#2214

SV014 ILMTsp

Set the current (torque) limit value in a special operation (absolute position initial setting, stopper control and
etc.).
This is a limit value in forward and reverse directions.
Set to "800" when not using.
Set this parameter as a proportion (%) to the stall current.
---Setting range---
0 - 999 (Stall current %)
However, when SV084/bitB=1, the setting range is from 0 to 32767 (Stall current 0.01%).
#2215

SV015 FFC

When a relative error in synchronous control is too large, set this parameter to the axis that is delaying.
The standard setting is "0". The standard setting in the SHG control is "100".
To adjust a relative error in acceleration/deceleration, increase the value by 50 at a time.
---Setting range---
0 to 999 (%)
#2216

SV016 LMC1

Set this parameter when the protrusion (that occurs due to the non-sensitive band by friction, torsion, back-
lash, etc.) at quadrant change is too large. This sets the compensation torque at quadrant change (when an
axis feed direction is reversed) by the proportion (%) to the stall torque. Whether to enable the lost motion
compensation and the method can be set with other parameters.
Type 2: When SV027/bit9, 8=10 (Compatible with obsolete type)
Set the type 2 method compensation torque. The standard setting is double the friction torque.
Related parameters: SV027/bit9,8, SV033/bitF, SV039, SV040, SV041, SV082/bit2
Type 3: When SV082/bit1=1
Set the compensation torque equivalent of dynamic friction amount of the type 3 method compensation
amount. The standard setting is double the dynamic friction torque.
Related parameters: SV041, SV082/bit2,1, SV085, SV086
To vary compensation amount according to the direction.
When SV041 (LMC2) is "0", compensate with the value of SV016 (LMC1) in both +/-directions.
If you wish to change the compensation amount depending on the command direction, set this and
SV041 (LMC2).
(SV016: + direction, SV041: - direction. However, the directions may be opposite depending on other set-
tings.)
When "-1" is set, the compensation will not be performed in the direction of the command.
---Setting range---
-1 to 200 (Stall current %)
Note that when SV082/bit2 is "1", the setting range is between -1 and 20000 (Stall current 0.01%).
Current limit value
Current limit value in special control
Acceleration rate feed forward gain
Lost motion compensation 1
515
IB-1501279-H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents