M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#2146
Blf_L1
Set the distance for specifying the compensation change rate in position-dependent increasing-type back-
lash compensation.
Blf_E1
Blf_E2
When "#2148 Blf_E1" is set to "0", the position-dependent increasing-type backlash compensation function
will be disabled.
---Setting range---
0.000 to 99999.999 (mm)
#2147
Blf_L2
Set the distance for specifying the compensation change rate in position-dependent increasing-type back-
lash compensation.
Blf_E1
Blf_E2
When "#2148 Blf_E1" is set to "0", the position-dependent increasing-type backlash compensation function
will be disabled.
---Setting range---
0.000 to 99999.999 (mm)
#2148
Blf_E1
Set the compensation amount for specifying the compensation change rate in position-dependent increas-
ing-type backlash compensation.
Blf_E1
Blf_E2
When "#2148 Blf_E1" is set to "0", the position-dependent increasing-type backlash compensation function
will be disabled.
---Setting range---
0 to 9999999 (Machine error compensation unit)
Blf_L2
Blf_L1
Blf_L2
Blf_L1
Blf_L2
Blf_L1
Reference distance for position-dependent increasing-
type backlash compensation 1
Reference distance for position-dependent increasing-
type backlash compensation 2
Reference amount of position-dependent increasing-
type backlash compensation 1
485
IB-1501279-H