M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#11010
Software keyboard
[M8]
Select with touch panel whether to use software keyboard.
0: Do not use
1: Use
2: Use (Note1)
(Note1) Software keyboard automatically appears on a specific screen.
#11011
Handy TERM. PW.
[M8]
Set the password used for the handy terminal customized downloading.
Blank (when "0" is set) and "0000" are regarded as no password.
Not the password of a new customizing file but the password of the customizing file downloaded to the last
handy terminal is set.
Set blank or "0000" when initially downloading.
---Setting range---
0000 to 9999
[C80]
Not used.
(PR)
#11012
16 axes for 1ch
Select the maximum number of axes (sum of the NC axis, spindle, and PLC axis) connected to the drive unit
interface (channel 1).
0: Up to 8 axes can be connected to channel 1.
1: Up to 16 axes can be connected to channel 1. This parameter is disabled when the extension unit is
connected. It is possible to connect only up to eight axes or less per channel.
#11013
3D_MChk
Select whether to enable the 3D machine interference check function.
0: Enable
1: Disable
#11014
Chk_len1
Set the 1st-step check distance when in 3D machine interference check mode.
The standard value is "30.000".
---Setting range---
0.000 to 99999.999(mm)
#11015
Chk_len2
Set the 2nd-step check distance when in 3D machine interference check mode.
The standard value is "5.000".
---Setting range---
0.000 to 99999.999(mm)
#11016
Expand_Rate
Set the model shape expansion rate to be used for 3D machine interference check. This parameter is used
for expanding a model shape to be used for 3D machine interference check. The interference check is per-
formed using a shape expanded by the amount of [Check length (mm) x Shape expansion rate (%)].
---Setting range---
0 to 300(%)
#11017
T-ofs set at run
Select whether to enable the tool compensation amount setting and life value setting during automatic oper-
ation and operation pause.
0: Disable
1: Enable
IB-1501279-H
Software keyboard
Handy terminal password
Connecting 16 axes for 1ch
Invalidate 3D machine interference check
1st-step interference check distance
2nd-step interference check distance
Shape expansion rate
Tool compensation amount setting during automatic
operation enabled
458