M800/M80/E80/C80 Series Alarm/Parameter Manual
14 Multi CPU Errors (A) [C80]
A01
Parameter A error
Details
The parameter setting is corrupted.
Remedy
Check the detailed information (parameter information) of the error by executing module diagnostics using
the engineering tool, and write the displayed parameter setting to the CPU module. If the same error code
is displayed again, the possible cause is a hardware failure of the data memory in the CPU module, the
memory card, or the module (I/O module or intelligent function module) connected. Please consult your lo-
cal Mitsubishi representative.
A01
Parameter A error
Details
The set value is out of range.
Remedy
Check the detailed information (parameter information) of the error by executing module diagnostics using
the engineering tool, and correct the parameter setting corresponding to the displayed number. If the same
error code is displayed again, the possible cause is a hardware failure of the data memory in the CPU mod-
ule, the memory card, or the module (I/O module or intelligent function module) connected. Please consult
your local Mitsubishi representative.
A01
Parameter A error
Details
Use of the function that is not supported by the module is enabled in parameter.
Remedy
Check the detailed information (parameter information) of the error by executing module diagnostics using
the engineering tool, and correct the parameter setting corresponding to the displayed number. If the same
error code is displayed again, the possible cause is a hardware failure of the data memory in the CPU mod-
ule, the memory card, or the module (I/O module or intelligent function module) connected. Please consult
your local Mitsubishi representative.
A01
Parameter A error
Details
A memory area cannot be ensured.
Remedy
Check the detailed information (parameter information) of the error by executing module diagnostics using
the engineering tool, display the error-detected area by clicking the [Error Jump] button, and increase the
capacity of the area. (If the capacity of the area cannot be increased, decrease the capacity of other areas.)
Reduce the number of labels or local devices used.
A01
Parameter A error
Details
The CPU module model set to the project using the engineering tool differs from that of the CPU module
actually mounted.
The operation set in the memory card parameters cannot be performed. (The boot function cannot be ex-
ecuted.)
Remedy
Correct the CPU module model set to the project in accordance with the CPU module actually mounted.
Delete the memory card parameter settings.
Remove the memory card so that the operation set in the memory card parameters will not be performed.
(Do not execute the boot operation.)
IB-1501279-H
184
2220
2221
2222
2224
2225