M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters

16.34 PROFIBUS-DP Parameters[M8]

(PR)
#57000+4(n-1)
[M8]
Select whether to allocate the devices to PX or PY of PROFIBUS-DP.
(Note) If 0 is set, the PROFIBUS allocation parameters of the n-th set are all disabled.
0: Disable
1: PX
2: PY
(PR)
#57001+4(n-1)
[M8]
Select the section of PROFIBUS-DP I/O data (PX/PY) to which the devices are allocated.
---Setting range---
0 to 31
(PR)
#57002+4(n-1)
[M8]
Select the device that is allocated to the section of PROFIBUS-DP I/O data(PX/PY).
(Note) The setting range varies according to the value of "#n I/O reg".
---Setting range---
X, Y, M, L, B, D, R or W
When "#n I/O reg" is "1", "Y" is out of the setting range.
When "#n I/O reg" is "2", "X" is out of the setting range.
(PR)
#57003+4(n-1)
[M8]
Select the 32 bytes of devices to which PROFIBUS-DP I/O data is allocated.
Specify the starting device number. (n=1 to 64)
* If the set value is out of the following ranges, an alarm occurs at the start of NC.
Hexadecimal setting:
X: 0 to 1C0, 300 to 500
Y: 0 to 1C0, 300 to 500
B: 0 to DF00
W: 0 to 2FF0
Decimal setting:
M: 0 to 61184
L: 0 to 768
D: 0 to 4080
R: 8300 to 9884, 18300 to 19884, 28300 to 29884
(Note) Due to the multi-project function, if the number of the first project points is smaller than the default
value, the range becomes narrower corresponding to the number of the first project points.
---Setting range---
The setting range varies according to the value of "#n dev name".
X, Y, B, W: 0 to FFFF
M, L, D, R: 0 to 65535
#n I/O reg
#n sect No.
#n dev name
#n dev No.
723
PROFIBUS I/O area
PROFIBUS section number
PROFIBUS device name
PROFIBUS device number