Mitsubishi Electric M800 Series Manual page 374

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#1510
DOOR_H
Select whether to shorten the time during which the axis is stopped when the door is opened.
0 : Use the conventional axis stop time.
1 : Shorten the axis stop time.
(Note) When the door interlock II signal is input via a ladder, the conventional axis stop time will be used.
#1511
DOORPm
Set the fixed device number for door interlock II signal input for each part system.
A device number from X01 to XFF can be specified.(Except X100.)
Device number "000" is invalid.
Set device number "100" when using no fixed device number for door interlock II signal input.
Related parameter: "#1154 pdoor" (Door interlock II for each part system)
---Setting range---
000 to 2FF (hexadecimal)
#1512
DOORPs
Set the fixed device number for door interlock II signal input for each part system.
(Set the same value as that of "#1155 DOOR_m".)
Related parameter: "#1154 pdoor" (Door interlock II for each part system)
---Setting range---
000 to 2FF (hexadecimal)
#1513
stapM
Set the M code for the synchronous tapping selection.
Select the synchronous tapping mode using the miscellaneous function code of the value set in this param-
eter. The M function command can be issued immediately before the tap command or in the same block.
This function is valid only when "1" is set in "#1272 ext08/bit1" (M-function synchronous tap cycle).
(Note) Do not use M00, 01 02, 30, 98, and 99.
---Setting range---
0 to 99999999
#1514
expLinax
Set the axis name for the linear axis used in exponential function interpolation.
---Setting range---
A to Z
#1515
expRotax
Set the axis name for the rotary axis used in exponential function interpolation.
---Setting range---
A to Z
#1516
mill_ax
Set the name of the rotary axis used in milling interpolation. Only one rotary axis can be set.
When there is no E command in issuing the G12.1 command, this parameter will be followed.
---Setting range---
A to Z
#1517
mill_C
Select the hypothetical axis command name for milling interpolation.
When there is no D command in issuing the milling interpolation command, this parameter will be followed.
0: Y axis command
1: Command rotary axis name.
Shorten door interlock II axis stop time
Signal input device 1 for door interlock II: for each part
system
Signal input device 2 for door interlock II: for each part
system
M code for synchronous tap selection
Exponential function interpolation linear axis
Exponential function interpolation rotary axis
Milling axis name
Milling interpolation hypothetical axis name