16 Machine Parameters
#11036

meas dir judge

Set the non-sensitive band to be used for judging the manual measurement direction. If the feedback position
fluctuates widely at the axis stop, set the fluctuation width or larger value in this set the parameter.
When set to "0", the band will be 1 (µm).
---Setting range---
0 to 1000 (µm)
0: 1 (µm)
#11037

R-Navi Index Type

[M8]
Select the machining surface indexing type in the R-Navi function.
0: Indexing type 1 (Only rotary axes move to perform indexing)
1: Indexing type 2 (Indexing is performed with the tool center point fixed to the position seen from the work-
piece)
[C80]
Not used.
#11038

T disp typ

Select the T display (tool command value) type on the monitor screen between displaying tool No. only or
displaying tool No. and compensation No. (L system only)
0: Display tool No. only
1: Display the tool command value (the combined value consisting of the tool No. and compensation No.)
last commanded by the program. Even in a manual value command, the program's tool command value
is displayed.
#11039

Cusr pos srch type

Set the availability of the cursor position search during single block stop when #11031 Cursor pos search=1
to 3.
0: Disable cursor position search during single block stop.
1: Enable cursor position search during single block stop.
Sub-program is displayed when selecting menus [Monitr]-[Edit] while single block stop is carried out during
sub-program with this parameter set to 1.
#11051
Direct Socket ON
[M8]
Select ON/OFF of the Direct Socket communication I/F.
0: OFF (Default)
1: ON
(Note) When the Direct Socket communication I/F is ON, applications that uses "#1926 Global IP address"
such as MS Configurator and GX Developer cannot be used.
[C80]
Not used.
#11052
LOG Sort Order
Select in which order to sort the operation log files (all logs) to be output.
0: Sort the data in chronologically ascending order separately for each log type.
1: Sort the data in chronologically ascending order for all the log types.
If the times and dates logged are identical, the log files are output in the order of key, touchscreen, alarm,
PLC signal, tool offset change, workpiece offset change and AC power.
#11054
Sp-stby disp type
Specify which magazine to display when Sp-stby is selected on the Spindle standby or Tool registration
screen.
0: Fixed to the magazine #1
1: The magazine selected by the menu (Magazine 1 to Magazine 5).
Non-sensitive band for manual measurement direction
judgment (for M system only)
R-Navi machining surface indexing type
T display (tool command value) type (For L system only)
Cursor position search type
Direct Socket communication I/F ON
Log data sorting order
Spindle-standby display type