Mitsubishi Electric M800 Series Manual page 511

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
#2198
G0tMin
Acceleration/Deceleration is carried out so that the acceleration/deceleration time will not become longer
than this parameter's setting when the acceleration/deceleration type of rapid traverse command is constant
inclination.
Set a value smaller than "#2004 G0tL".
This parameter is enabled when "#1200 G0_acc" is constant inclination type.
This parameter is enabled only during fixed cycle if "#1253 set25 bit2" (Acceleration/Deceleration mode
change in hole drilling cycle) is enabled even if "#1200 G0_acc" is constant inclination type.
This parameter is disabled if 0 or a value larger than "#2004 G0tL" is set.
---Setting range---
0 to 4000 (ms)
#2199
G1tMin
Acceleration/Deceleration is carried out so that the acceleration/deceleration time will not become longer
than this parameter's setting when the acceleration/deceleration type of linear interpolation command is con-
stant inclination.
Set a value smaller than "#2007 G1tL".
This parameter is enabled when "#1201 G1_acc" is constant inclination type.
This parameter is enabled only during fixed cycle if "#1253 set25 bit2" (Acceleration/Deceleration mode
change in hole drilling cycle) is enabled even if "#1200 G0_acc" is constant inclination type.
This parameter is disabled if 0 or a value larger than "#2007 G1tL" is set.
---Setting range---
0 to 4000 (ms)
#2561
VBL2 VG1
Set the changeover speed at speed normalization.
Set a value smaller than that in "#2562 VBL2 VG0".
Normally, the "#2561 VBL2 VG1" value corresponds to the cutting feedrate, the "#2562 VBL2 VG0" value to
the rapid traverse rate.
---Setting range---
1 to 1000000 (mm/min)
#2562
VBL2 VG0
Set the changeover speed at speed normalization.
Set a value greater than that in "#2561 VBL2 VG1".
Normally, the "#2561 VBL2 VG1" value corresponds to the cutting feedrate, the "#2562 VBL2 VG0" value to
the rapid traverse rate.
---Setting range---
1 to 1000000 (mm/min)
#2563
VBL2 P1
Set the most plus (+) side stroke position among the three.
Set the parameters VBL2 P1 to P3 to be "VBL2 P1 > VBL2 P2 > VBL2 P3".
Normally, divide the axis's stroke by four, and set a dividing position (except for the both ends) to be a stroke
position.
---Setting range---
-99999.999 to 99999.999 (mm)
#2564
VBL2 P2
Set the middle stroke position among the three.
Set the parameters VBL2 P1 to P3 to be "VBL2 P1 > VBL2 P2 > VBL2 P3".
Normally, divide the axis's stroke by four, and set a dividing position (except for the both ends) to be a stroke
position.
---Setting range---
-99999.999 to 99999.999 (mm)
IB-1501279-H
Minimum time constant for rapid traverse constant in-
clination acc./dec.
Minimum time constant for cutting feed constant incli-
nation acc./dec.
Variable backlash comp II Changeover speed 1
Variable backlash comp II Changeover speed 2
Variable backlash comp II Stroke position 1
Variable backlash comp II Stroke position 2
494

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C80 seriesM80 seriesE80 series

Table of Contents