M800/M80/E80/C80 Series Alarm/Parameter Manual
16 Machine Parameters
(PR)
#1392
StartTimeIPC
Specify when to start accumulating power consumption to create the history.
The accumulated power consumption history can be obtained according to this parameter along with "#1371
PwrIntegIntvl" (Power consumption accumulation interval).
---Setting range---
0 to 23 (o'clock)
#1393
Efficiency(PwrCal)
Specify the efficiency for calculating power consumption.
This value is used for calculating the drive system power consumption.
When 0 is set, the efficiency is treated as 70(%).
If the drive system power consumption computed by the NC is different from that measured by a measuring
device, this parameter is used to adjust the drive system power consumption of the NC.
---Setting range---
0 to 100 (%)
(PR)
#1395
H1_pno
Specify the connection destination of the 1st handle.
bit F to 8: Remote I/O unit station 1 to 40(HEX)
bit 7 to 4: Handle connection destination
0: CNC unit
1 to 2: Remote I/O unit
5: Expansion unit
F: Operation panel I/O unit
bit 3 to 0: Handle connection channel 1 to 3 (3 is only valid for operation panel)
(Ex)
0001: Handle 1 connected to the CNC unit
2421: Handle 1 of 36th station for remote I/O unit connected to RIO2
00F3: Handle 3 of operation panel I/O unit connected to RIO3
(Note 1) When the specified destination is not implemented, handle movement is not performed.
(Note 2) When all the H1_pno to H3_pno are set to 0000, handles are automatically allocated.
Other than above, 0000 setting is the same connection as 0001 setting.
---Setting range---
0x0000 to 0xFFFF
(PR)
#1396
H2_pno
Specify the connection destination of the 2nd handle.
bit F to 8: Remote I/O unit station 1 to 40(HEX)
bit 7 to 4: Handle connection destination
0: CNC unit
1 to 2: Remote I/O unit
5: Expansion unit
F: Operation panel I/O unit
bit 3 to 0: Handle connection channel 1 to 3 (3 is only valid for operation panel)
(Ex)
0001: Handle 1 connected to the CNC unit
2421: Handle 1 of 36th station for remote I/O unit connected to RIO2
00F3: Handle 3 of operation panel I/O unit connected to RIO3
(Note 1) When the specified destination is not implemented, handle movement is not performed.
(Note 2) When all the H1_pno to H3_pno are set to 0000, handles are automatically allocated.
Other than above, 0000 setting is the same connection as 0001 setting.
---Setting range---
0x0000 to 0xFFFF
IB-1501279-H
Power consumption accumulation start time
Efficiency for power consumption computation
1st handle selection
2nd handle selection
440