ABB ACS560 Firmware Manual page 152

General purpose drives
Hide thumbs Also See for ACS560:
Table of Contents

Advertisement

152 Control macros
Additional Notes
Some inputs and settings are set automatically as follows:
No.
12.20
12.30
19.11
19.14
20.01
20.06
20.08
22.22
22.23
23.11
26.11
26.20
99.04
Name (Input/Setting)
AI1 scaled at AI1 max
AI2 scaled at AI2 max
Ext1/Ext2 selection
Ext2 control mode
Ext1 commands
Ext2 commands
Ext2 in1 source
Constant speed sel1
Constant speed sel2
Ramp set selection
Torque ref1 source
Torque reversal
Motor control mode
Value
1500.000
100.000
DI3
Torque
In1 Start fwd; In2 Start rev
In1 Start
DI1
Always off
Always off
Acc/Dec time 1
AI2 scaled
DI2
Vector