Coils (0Xxxx Reference Set) - ABB ACS560 Firmware Manual

General purpose drives
Table of Contents

Advertisement

Fieldbus control through the embedded fieldbus interface (EFB) 461

Coils (0xxxx reference set)

Coils are 1-bit read/write values. Control Word bits are exposed with this data type.
The table below summarizes the Modbus coils (0xxxx reference set). Note that the
references are 1-based index which match the address transmitted on the wire.
Reference ABB Drives profile
000001
OFF1_CONTROL
000002
OFF2_CONTROL
000003
OFF3_CONTROL
000004
INHIBIT_OPERATION
000005
RAMP_OUT_ZERO
000006
RAMP_HOLD
000007
RAMP_IN_ZERO
000008
RESET
000009
JOGGING_1
000010
JOGGING_2
000011
REMOTE_CMD
000012
EXT_CTRL_LOC
000013
USER_0
000014
USER_1
000015
USER_2
000016
USER_3
000017
Reserved
000018
Reserved
000019
Reserved
000020
Reserved
000021
Reserved
000022
Reserved
000023
Reserved
000024
Reserved
000025
Reserved
000026
Reserved
000027
Reserved
000028
Reserved
000029
Reserved
000030
Reserved
000031
Reserved
000032
Reserved
DCU Profile
STOP
START
Reserved
Reserved
RESET
EXT2
RUN_DISABLE
STOPMODE_RAMP
STOPMODE_EMERGENCY_RAMP
STOPMODE_COAST
Reserved
RAMP_OUT_ZERO
RAMP_HOLD
RAMP_IN_ZERO
Reserved
Reserved
FB_LOCAL_CTL
FB_LOCAL_REF
Reserved
Reserved
Reserved
Reserved
USER_0
USER_1
USER_2
USER_3
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved