ABB ACS560 Firmware Manual page 202

General purpose drives
Table of Contents

Advertisement

202 Parameters
No.
Name/Value
In1P Start; In2 Stop;
In3 Dir
In1P Start fwd; In2P
Start rev; In3 Stop
Control panel
Fieldbus A
Embedded fieldbus
20.02
Ext1 start trigger
type
Edge
Level
20.03
Ext1 in1 source
Always off
Always on
DI1
DI2
Description
The sources of the start and stop commands are selected by
parameters
20.03 Ext1 in1 source
The source selected by
direction. The state transitions of the source bits are
interpreted as follows:
State of
State of
source 1
source 2
(20.03)
(20.04)
0 - > 1
1
0 - > 1
1
Any
0
Notes:
• Parameter
20.02 Ext1 start trigger type
this setting.
• When source 2 is 0, the Start and Stop keys on the control
panel are disabled.
The sources of the start and stop commands are selected by
parameters
20.03 Ext1 in1
20.05 Ext1 in3
source. The source selected by
source
determines the stop. The state transitions of the
source bits are interpreted as follows:
State of
State of
source 1
source 2
(20.03)
(20.04)
0 - > 1
Any
0 - > 1
Any
Any
Any
Note: Parameter
20.02 Ext1 start trigger type
with this setting.
The start and stop commands are taken from the control
panel (or PC connected to the panel connector).
The start and stop commands are taken from fieldbus adapter
A.
Note: Set also
20.02 Ext1 start trigger type
The start and stop commands are taken from the embedded
fieldbus interface.
Note: Set also
20.02 Ext1 start trigger type
Defines whether the start signal for external control location
EXT1 is edge-triggered or level-triggered.
Note: This parameter is not effective if a pulse-type start
signal is selected. See the descriptions of the selections of
parameter
20.01 Ext1
commands.
The start signal is edge-triggered.
The start signal is level-triggered.
Selects source 1 for parameter
0 (always off).
1 (always on).
Digital input DI1
(10.02 DI delayed
Digital input DI2
(10.02 DI delayed
and
20.04 Ext1 in2
20.05 Ext1 in3 source
determines the
State of
source 3
(20.05)
0
Start forward
1
Start reverse
Any
has no effect with
source,
20.04 Ext1 in2 source
20.05 Ext1 in3
State of
source 3
(20.05)
1
Start forward
1
Start reverse
0
has no effect
to Level.
to Level.
20.01 Ext1
commands.
status, bit 0).
status, bit 1).
Def/FbEq16
5
source.
Command
Stop
6
and
Command
Stop
11
12
14
Level
0
1
DI1
0
1
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents