ABB ACS560 Firmware Manual page 279

General purpose drives
Table of Contents

Advertisement

No.
Name/Value
34.100 Timed function 1
Bit
Name
0
Timer 1
1
Timer 2
2
Timer 3
3
Timer 4
4
Timer 5
5
Timer 6
6
Timer 7
7
Timer 8
8
Timer 9
9
Timer 10
10
Timer 11
11
Timer 12
12...15 Reserved
0b0000...0b1111
34.101 Timed function 2
34.102 Timed function 3
34.110
Boost time function
Bit
Name
0
Timed function 1
1
Timed function 2
2
Timed function 3
3...15
Reserved
0b0000...0b1111
34.111
Boost time
activation source
Off
On
DI1
DI2
DI3
DI4
DI5
DI6
Description
Defines which timers are connected to combined timer 1.
0 = Not connected.
1 = Connected.
See
34.01 Timed functions
Description
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
Timers connected to combined timer 1.
Defines which timers are connected to combined timer 2.
See
34.01 Timed functions
Defines which timers are connected to combined timer 3.
See
34.01 Timed functions
Defines which combined timers (that is, timers that are
connected to the combined timers) are activated with the
extra time function.
Description
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
0 = Inactive. 1 = Active.
Combined timers including the extra timer.
Selects the source of extra time activation signal.
0 = Disabled.
1 = Enabled.
0.
1.
Digital input DI1
(10.02 DI delayed
Digital input DI2
(10.02 DI delayed
Digital input DI3
(10.02 DI delayed
Digital input DI4
(10.02 DI delayed
Digital input DI5
(10.02 DI delayed
Digital input DI6
(10.02 DI delayed
status.
status.
status.
status, bit 0).
status, bit 1).
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
Parameters 279
Def/FbEq16
0b0000
1 = 1
0b0000
0b0000
0b0000
1 = 1
Off
0
1
2
3
4
5
6
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents