ABB ACS560 Firmware Manual page 353

General purpose drives
Table of Contents

Advertisement

No.
Name/Value
95.02
Adaptive voltage
limits
Disable
Enable
95.03
Estimated AC
supply voltage
0...65535 V
95.04
Control board
supply
Internal 24V
External 24V
95.15
Special HW
settings
Bit
Name
0
Reserved
1
ABB Sine filter
2...15
Reserved
0b0000...0b1111
Description
Enables adaptive voltage limits.
Adaptive voltage limits can be used if, for example, an IGBT
supply unit is used to raise the DC voltage level. If the
communication between the inverter and IGBT supply unit is
active, the voltage limits are related to the DC voltage
reference from the IGBT supply unit. Otherwise the limits are
calculated based on the measured DC voltage at the end of
the pre-charging sequence.
This function is also useful if the AC supply voltage to the
drive is high, as the warning levels are raised accordingly.
Adaptive voltage limits disabled.
Adaptive voltage limits enabled.
AC supply voltage estimated by calculation. Estimation is
done every time the drive is powered up and is based on the
rise speed of voltage level of the DC bus while the drive
charges the DC bus.
Voltage.
Specifies how the control board of the drive is powered.
The drive control board is powered from the drive power unit
it is connected to.
The drive control board is powered from an external power
supply.
Contains hardware-related settings that can be enabled and
disabled by toggling the specific bits.
Note: The installation of the hardware specified by this
parameter may require derating of drive output, or impose
other limitations. Refer to the hardware manual of the drive.
Information
1 = An ABB sine filter is connected to the output of the drive.
Hardware options configuration word.
Parameters 353
Def/FbEq16
Disable
0
1
0
10 = 1 V
Internal 24V
0
1
0b0000
1 = 1

Hide quick links: