ABB ACS560 Firmware Manual page 350

General purpose drives
Table of Contents

Advertisement

350 Parameters
No.
Name/Value
76.72
Maximum wear
imbalance
0.00...1000000.00
h
76.73
Autochange level
0.0...300.0%
76.74
Autochange
auxiliary PFC
All motors
Aux motors only
76.81
PFC interlock 1
Interlocked. PFC
motor is not in use
Available. PFC
motor is available
DI1
DI2
DI3
DI4
DI5
DI6
Timed function 1
Timed function 2
Timed function 3
Other [bit]
76.82
PFC interlock 2
Description
Specifies the maximum wear imbalance, or difference in
running times between any motor, used by the
setting of parameter
76.70 PFC
Time.
Upper speed limit for the Autochange to occur. The
Autochange occurs when:
• the condition defined in
and,
• the speed of the drive motor
the speed limit defined in this parameter.
Note: When the value is selected as 0%, this speed limit
check is disabled.
Speed/frequency in percentage of the nominal speed or
frequency of the drive motor.
Selects whether only auxiliary motors or all motors are
included in the Autochange function.
All motors, including the one connected to the drive
participates in the autochange. The Autochange logic will
connect the drive to each of the motors according to setting of
parameter
76.70 PFC
autochangee.
Note: The first motor (PFC1) also requires the appropriate
hardware contactor connections and PFC1 must be defined
in one of the relay output source parameters.
Only auxiliary (direct-on-line) motors are affected by the
autochange function.
Note: PFC1 refers to the motor that is fixed to the drive and
must not be selected in any of the relay output source
parameters. Only the starting order of the auxiliary motors will
be rotated.
Defines if the PFC motor 1 can be started. An interlocked
PFC motor cannot be started.
0 = Interlocked (not available), 1 = Available.
PFC motor is interlocked and not available.
PFC motor is available.
Digital input DI1
(10.02 DI delayed
Digital input DI2
(10.02 DI delayed
Digital input DI3
(10.02 DI delayed
Digital input DI4
(10.02 DI delayed
Digital input DI5
(10.02 DI delayed
Digital input DI6
(10.02 DI delayed
Bit 0 of
34.01 Timed functions status
Bit 1 of
34.01 Timed functions status
Bit 2 of
34.01 Timed functions status
Source selection (see
Terms and abbreviations
See parameter
76.82 PFC interlock
Even wear
autochange.
76.70 PFC autochange
01.03 Motor speed %
status, bit 0).
status, bit 1).
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
(see page 273).
(see page 273).
(see page 273).
on page 162). -
1.
Def/FbEq16
10.00 h
1 = 1 h
100.0%
is fulfilled
is below
1 = 1%
Aux motors
only
0
1
Available.
PFC motor is
available
0
1
2
3
4
5
6
7
8
9
10
Available.
PFC motor is
available