Motor Data - ABB ACS560 Firmware Manual

General purpose drives
Hide thumbs Also See for ACS560:
Table of Contents

Advertisement

No.
Name/Value
Motor parameters
98.02
Rs user
0.00000...0.50000
p.u.
98.03
Rr user
0.00000...0.50000
p.u.
98.04
Lm user
0.00000...10.00000
p.u.
98.05
SigmaL user
0.00000...1.00000
p.u.
98.09
Rs user SI
0.00000...100.0000
0 ohm
98.10
Rr user SI
0.00000...100.0000
0 ohm
98.11
Lm user SI
0.00...100000.00
mH
98.12
SigmaL user SI
0.00...100000.00
mH

99 Motor data

99.03
Motor type
Asynchronous
motor
99.04
Motor control mode
Vector
Description
The values of parameters 98.02...
motor model.
Defines the stator resistance R
With a star-connected motor, R
winding. With a delta-connected motor, R
resistance of one winding.
Stator resistance in per unit.
Defines the rotor resistance R
Rotor resistance in per unit.
Defines the main inductance L
Main inductance in per unit.
Defines the leakage inductance
Leakage inductance in per unit.
Defines the stator resistance R
Stator resistance.
Defines the rotor resistance R
Rotor resistance.
Defines the main inductance L
Main inductance.
Defines the leakage inductance
Leakage inductance.
Motor configuration settings.
Selects the motor type.
Note: This parameter cannot be changed while the drive is
running.
Standard squirrel cage AC induction motor (asynchronous
induction motor).
Selects the motor control mode.
Vector control. Vector control has better accuracy than scalar
control but cannot be used in all situations (see selection
Scalar
below).
Requires motor identification run (ID run). See parameter
99.13 ID run
requested.
Note: In vector control the drive performs a standstill ID run at
the first start if ID run has not been previously performed. A
new start command is required after standstill ID run.
Note: To achieve a better motor control performance, you can
perform a normal ID run without load.
See also section
Operating modes of the drive
98.12
are used as the
of the motor model.
S
is the resistance of one
S
is one-third of the
S
of the motor model.
R
of the motor model.
M
L
.
S
of the motor model.
S
of the motor model.
R
of the motor model.
M
L
.
S
(page 37).
Parameters 365
Def/FbEq16
1
0.00000 p.u.
-
0.00000 p.u.
-
0.00000 p.u.
-
0.00000 p.u.
-
0.00000 ohm
-
0.00000 ohm
-
0.00 mH
1 = 10000
mH
0.00 mH
1 = 10000
mH
Asynchro-
nous motor
0
Scalar
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents