ABB ACS560 Firmware Manual page 271

General purpose drives
Table of Contents

Advertisement

No.
Name/Value
32.45
Supervision 5
function
Disabled
Low
High
Abs low
Abs high
Both
Abs both
Hysteresis
32.46
Supervision 5
action
No action
Warning
Fault
Fault if running
32.47
Supervision 5
signal
32.48
Supervision 5 filter
time
0.000 ... 30.000 s
32.49
Supervision 5 low
-21474836.00...
21474836.00
32.50
Supervision 5 high
-21474836.00...
21474836.00
32.51
Supervision 5
hysteresis
0.00...100000.00
Description
Selects the mode of signal supervision function 5. Determines
how the monitored signal (see parameter 32.47) is compared
to its low and high limits
action to be taken when the condition is fulfilled is selected by
32.46.
Signal supervision 5 not in use.
Action is taken whenever the signal falls below its low limit.
Action is taken whenever the signal rises above its high limit.
Action is taken whenever the absolute value of the signal falls
below its (absolute) low limit.
Action is taken whenever the absolute value of the signal
rises above its (absolute) high limit.
Action is taken whenever the signal falls below its low limit or
rises above its high limit.
Action is taken whenever the absolute value of the signal falls
below its (absolute) low limit or rises above its (absolute) high
limit.
Action is taken whenever the signal falls below its (hysteresis)
low limit or rises above its (hysteresis) high limit.
Selects whether the drive generates a fault, warning or
neither when the value monitored by signal supervision 5
exceeds its limits.
Note: This parameter does not affect the status indicated by
32.01 Supervision
status.
No warning or fault generated.
Warning
A8B4 Signal supervision 5
Drive trips on fault
80B4 Signal supervision
Drive trips on fault
80B0 Signal supervision 1
running.
Selects the signal to be monitored by signal supervision
function 5.
For the available selections, see parameter
Supervision 1
signal.
Defines a filter time constant for the signal monitored by
signal supervision 5.
Signal filter time.
Defines the low limit for signal supervision 5.
Low limit.
Defines the high limit for signal supervision 5.
High limit.
Defines the hysteresis for the signal monitored by signal
supervision 5.
Hysteresis.
(32.49
and
32.40
respectively). The
is generated.
5.
if the motor is
32.07
Parameters 271
Def/FbEq16
Disabled
0
1
2
3
4
5
6
7
No action
0
1
2
3
Zero
0.000 s
1000 = 1 s
0.00
-
0.00
-
0.00
-