ABB ACS560 Firmware Manual page 253

General purpose drives
Table of Contents

Advertisement

No.
Name/Value
30.12
Maximum speed
-30000.00...
30000.00 rpm
30.13
Minimum frequency
-500.00...500.00
Hz
30.14
Maximum
frequency
-500.00...500.00
Hz
30.17
Maximum current
0.00...3.24 A
Description
Defines the maximum allowed speed.
Note: This parameter does not affect the speed acceleration
and deceleration ramp times. See parameter
scaling.
WARNING! This value must not be lower than
Minimum
speed.
WARNING! In speed control mode only. In frequency
control mode, use frequency limits
Maximum speed.
Defines the minimum allowed frequency.
WARNING! This value must not be higher than
Maximum
frequency.
WARNING! in frequency control mode only.
Minimum frequency.
Defines the maximum allowed frequency.
Note: This parameter does not affect the frequency
acceleration and deceleration ramp times. See parameter
46.02 Frequency
scaling.
WARNING! This value must not be lower than
Minimum
frequency.
WARNING! in frequency control mode only.
Maximum frequency.
Defines the maximum allowed drive current.
The system sets the default value to 90% of the rated
current. If required, you can increase the parameter value
by 10%.
Note: The maximum current range and default value
depends on the drive type.
Maximum drive current.
Parameters 253
Def/FbEq16
1500.00 rpm
46.01 Speed
30.11
(30.13
and 30.14).
See par.
46.01
-50.00 Hz
30.14
See par.
46.02
50.00 Hz
30.13
See par.
46.02
2.92 A
1 = 1 A

Hide quick links: